40HP Carlyle Carrier Compressors 06EA299600 foar airconditioning
CARLYLE COMPRESSOR D Series
Carlyle | Carlyle Service | Temp. | Motor | CFM | CFH | Nee. | Nee. | Potinsjeel | Oalje | Low Temp. | Med Temp. | |
OEM Model | Ferfanging | Berik | Grutte | of | of | Unloading | Kosten | EER | EER | |||
Nûmer | Model | R404a | HP | Cyl | Heads | Stadia | Pints | R404a @ | R404a @ | |||
-0.003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 oan 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 oan 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 oan 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 oan 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 oant 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 oan 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 oan 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 oan 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 oant 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 oant 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 oant 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 oan 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 oan 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 oant 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 oan 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 oant 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 oan 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 oan 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 oant 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
CARLYLE COMPRESSOR ESerie
Carlyle | Carlyle Service | Temp. | Motor | CFM | CFH | Nee. | Nee. | Potinsjeel | Oalje | Low Temp. | Med Temp. | |
OEM Model | Ferfanging | Berik | Grutte | of | of | Unloading | Kosten | EER | EER | |||
Nûmer | Model | R404a | HP | Cyl | Heads | Stadia | Pints | R404a @ | R404a @ | |||
-0.003846154 | 20/110/65 | |||||||||||
06DM8080… | 06DM8086… | 0 oan 50 | 3 | 8 | 480 | 2 | 1 | 0 | 3 | 8.4 | ||
06DR1090… | 06DR1086… | -40 oan 0 | 2 | 8.7 | 522 | 2 | 1 | 0 | 3 | 5.4 | ||
06DR0130… | 06DR0136… | -40 oan 0 | 3 | 13 | 786 | 4 | 2 | 1 | 4.5 | 5.3 | ||
06DM3130… | 06DM3136… | 0 oan 50 | 5 | 13 | 786 | 4 | 2 | 1 | 4.5 | 9.3 | ||
06DR3160… | 06DR3166… | -40 oant 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 5.4 | 9.3 | |
06DM3160… | 06DM3166… | 0 oan 25 | 5 | 15.9 | 954 | 4 | 2 | 1 | 4.5 | 9 | ||
06DR7180… | 06DR7186… | -40 oan 0 | 5 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 5.5 | ||
06DA8182… | 06DS8186… | 0 oan 50 | 6 1/2 | 18.3 | 1100 | 4 | 2 | 1 | 5.5 | 8.6 | ||
06DR8200… | 06DR8206… | -40 oant 40 | 6 1/2 | 20 | 1200 | 4 | 2 | 1 | 5.5 | 5.6 | 9.4 | |
06DR7240… | 06DR7246… | -40 oant 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DR7250… | 06DR7256… | -40 oant 25 | 6 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 5.6 | 9.2 | |
06DA8242… | 06DS8246 | 0 oan 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DA8252… | 06DS8256… | 0 oan 50 | 7 1/2 | 23.9 | 1435 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR2280… | 06DR2286… | -40 oant 30 | 7 1/2 | 28 | 1680 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DA3282… | 06DS3286… | 0 oan 50 | 10 | 28 | 1680 | 6 | 3 | 2 | 8 | 8.6 | ||
06DR3370… | 06DR3376… | -40 oant 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 5.7 | 9.2 | |
06DM3370… | 06DM3376… | 0 oan 25 | 10 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DA5372… | 06DA5376… | 0 oan 50 | 15 | 37.1 | 2225 | 6 | 3 | 2 | 8 | 8.7 | ||
06DR5410… | 06DR5416… | -40 oant 30 | 15 | 41 | 2460 | 6 | 3 | 2 | 8 | 5 | 9 |
Beskriuwing
Carlyle 06D / E semi-hermetyske kompressors binne by útstek geskikt foar kommersjele koeling, airconditioning, proses koeling, en miljeu keamers.Se binne ekstreem fleksibel en kinne brûkt wurde mei in protte fan 'e nije HFC-koelmidden lykas R-507, R-404A, R-407C en R-134a, neist de konvinsjonele koelmiddelen (R-12, R-22, en R -502).De kompressors kinne wurde eksploitearre op 50 of 60 hertz.In protte fan 'e promininte skaaimerken fan' e 06D / E-kompressors wurde hjirûnder neamd.
Funksjes:
- Automatysk omkearbere oaljepomp mei hege trochstreaming leveret oaljesmering mei positive ferpleatsing.
- Crankcase venting systeem lykmakket druk by opstarten en soarget foar oalje werom nei sump.
- Oversize sump hâldt ekstra oalje yn crankcase om foar te kommen dat nivo's falle ûnder feilich smeerberik by oerstreamde starts.
- Contoured pistons legere silinder klaring te fergrutsjen compressor kapasiteit en effisjinsje.
- Kleppen mei hege effisjinsje jouwe ferhege koelmiddelstream en legere drukfallen.
- Elektroanyske oalje-druk switch.