Renewable Design for Dc Inverter Ac With T3 Compressor - Copeland Refrigerator Scroll Compressor tandem units, Copeland 5HP Refrigerator Scroll Compressor – Hengyi

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Assume full duty to satisfy all demands of our clients; reach steady advancements by marketing the development of our purchasers; grow to be the final permanent cooperative partner of clientele and maximize the interests of customers for Dc Fridge Compressor , Compressor Bitzer , National Refrigerator Compressor , We always welcome new and old customers presents us with valuable advice and proposals for cooperation, let us grow and develop together, and to contribute to our community and staff!
Renewable Design for Dc Inverter Ac With T3 Compressor - Copeland Refrigerator Scroll Compressor tandem units, Copeland 5HP Refrigerator Scroll Compressor – Hengyi Detail:

Product Paramenters

Model

ZR61KC-TFD-522

Horse Power (HP)

5.1HP

Voltage

380V-440V/3Ph/50HZ-60HZ

Refrigerant

R22

Cooling Capacity(W)

14550W

Cooling Capacity (Btu/h)

49470 Btu/h

Displacement (cc/Rev)

82.6 cc/Rev

Input power (W)

4430W

Current(A)

8.2A

COP(w/w)

3.28w/w

EER(Btu/Wh)

11.2Btu/Wh

Net weight(kg)

36.1kg

Packing

Wooden Case

 

Dirty blockage failures are caused by excess impurities in the refrigeration system. The main sources of impurities in the system are: dust and metal shavings during the manufacturing process of the refrigerator, the oxide layer on the inner wall surface falls off when the pipeline is welded, the inner and outer surfaces of each component are not cleaned during the processing, and the pipeline is not tightly sealed Dust enters In the tube, the refrigerating machine oil and refrigerant contain impurities, and the desiccant powder of poor quality in the drying filter. Most of these impurities and powders are removed by the drier when they flow through the drier. When there are many impurities in the drier, some fine dirt and impurities are brought into the capillary by the refrigerant with a higher flow rate, and in the curved section of the capillary The parts with larger resistance stay and accumulate, and the resistance becomes larger and larger, which makes it easier for impurities to stay until the capillary is blocked and the refrigeration system cannot circulate. In addition, the distance between the capillary tube and the filter screen in the filter drier is too close to cause dirty blockage failure; in addition, it is also easy to weld the capillary tube orifice when welding the capillary tube and the filter drier.

After the refrigeration system is dirty and blocked, because the refrigerant cannot be circulated, the compressor runs continuously, the evaporator is not cold, the condenser is not hot, the compressor shell is not hot, and there is no airflow in the evaporator. If partially clogged, the evaporator will feel cool or icy, but not frosted. The outer surfaces of the filter drier and capillary were cold to the touch, frosted, or even hoarfrost. This is because when the refrigerant flows through the micro-blocked filter drier or capillary, throttling and depressurization will occur, so that the refrigerant flowing through the blockage will expand, vaporize, and absorb heat, resulting in condensation or condensation on the outer surface of the blockage. Frost.

The difference between ice blockage and dirty blockage: after the ice blockage occurs for a period of time, the refrigeration can be resumed, forming a period of time-opening, blocking for a while, blocking and then clearing, and a periodical repetition of clearing and blocking. And after the dirty blockage occurs, it cannot be cooled.

In addition to the dirty blockage of the capillary, if there are too many impurities in the system, the drying filter will gradually be blocked. Because the filter itself has a limited capacity to filter out the dirt and impurities, blockage will occur due to the continuous accumulation of impurities.


Product detail pictures:

Renewable Design for Dc Inverter Ac With T3 Compressor -
 Copeland Refrigerator Scroll Compressor tandem units, Copeland 5HP Refrigerator Scroll Compressor – Hengyi detail pictures

Renewable Design for Dc Inverter Ac With T3 Compressor -
 Copeland Refrigerator Scroll Compressor tandem units, Copeland 5HP Refrigerator Scroll Compressor – Hengyi detail pictures

Renewable Design for Dc Inverter Ac With T3 Compressor -
 Copeland Refrigerator Scroll Compressor tandem units, Copeland 5HP Refrigerator Scroll Compressor – Hengyi detail pictures


Related Product Guide:

Sincerity, Innovation, Rigorousness, and Efficiency may be the persistent conception of our organization for that long-term to establish jointly with customers for mutual reciprocity and mutual gain for Renewable Design for Dc Inverter Ac With T3 Compressor - Copeland Refrigerator Scroll Compressor tandem units, Copeland 5HP Refrigerator Scroll Compressor – Hengyi , The product will supply to all over the world, such as: South Korea , Gabon , Jordan , We pursue the management tenet of Quality is superior, Service is supreme, Reputation is first, and will sincerely create and share success with all clients. We welcome you to contact us for more information and look forward to working with you.
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Jeff Wolfe from Malta - 2018.11.22 12:28
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Hilary from Mauritania - 2018.06.21 17:11
    Write your message here and send it to us